Description
Medical device for administering drugs through inhalation, whose inhalation therapy and medicines must be prescribed by your doctor. Treatment of respiratory diseases.
Drugs must be prescribed by a doctor who has assessed the patient's general condition.
Assembly
Assemble the nozzle on the top.
Place the valve on the grain size regulator with the flat side facing down and aligning the hole with the position ribs, then screw the selector onto the regulator's threaded pin until it stops.
Rotate the assembled regulator to ensure it rotates freely and that the selector moves up and down between positions.
Insert and press the previously assembled grain size regulator all the way in, keeping it in a horizontal position, in the upper part, making sure the selector bulkheads match the recess in the upper part.
Insert the upper part assembled at the bottom and attach it by turning it clockwise.
Mode of use
Before use, wash your hands thoroughly.
During the application it is recommended to protect itself adequately from any dripping.
This nebulizer is suitable for the administration of medicinal substances (solutions and suspensions), for which aerosolic administration is expected, such substances must be prescribed by the doctor.
In the case of too dense substances it may be necessary to dilute with suitable physiological solution, according to prescription.
Insert the power cord plug into an electrical socket corresponding to the voltage of the appliance.
The same must be positioned in such a way that it is not difficult to operate the disconnection from the electricity network.
Pour the medicine prescribed by your doctor at the bottom.
Insert the upper part of the amp at the bottom, close the amp by turning the upper part clockwise.
Connect the accessories.
Set the amp selector for the desired granulometry.
Sit comfortably holding the nebulizer, lean the mouthpiece or use the nasal (where required) or mask.
In case you use the mask accessory to support the face.
Put the appliance into operation by activating the switch and inhale and exhale deeply.
It is recommended after the inspiration to hold your breath for an instant so that inhaled aerosol drips can settle.
Exhale slowly.
Finish the application, turn off the appliance and disconnect it from the power grid.
Cleaning and disinfection
Switch off the appliance before any hygienic preparation operation and disconnect it from the power grid.
Compressor and external unit of the pipe: use only a moistened cloth with antibacterial cleaner (non abrasive and solvent-free of any kind).
Nebulizer and accessories: open the nebulizer by turning the top anti-clockwise, detach the nozzle and the speed selector from the top. Then proceed according to the instructions below.
Sanification.
Before and after each use, sanitize the nebulizer and accessories by choosing one of the methods described below.
Method A: sanitize the accessories under drinking hot water (about 40°C) with mild detergent for dishes (not abrasive).
Method B: sanitizing dishwasher accessories with hot cycle (70°C).
Method C: sanitize the accessories by dive into a solution with 50% water and 50% white vinegar, then rinse thoroughly with drinking hot water (about 40°C). After sanitizing the accessories shake them energetically and attach them on a paper napkin, or alternatively wipe them with a hot air jet (for example hairdryer).
Disinfection.
After sanitizing the nebulizer and accessories, disinfect them by choosing one of the methods provided and described below. Each method is feasible for a limited number of times.
Method A: Procuring an electrolytic chloxydant disinfectant (active ingredient: sodium hypochlorite), specific for disinfection available in all pharmacies.
Execution:
- Fill a container of dimensions suitable to contain all individual components to be disinfected with a solution based on drinking water and disinfectant, respecting the proportions indicated on the packaging of the disinfectant.
- Completely immerse every single component in the solution, taking care to avoid the formation of air bubbles in contact with the components. Leave the components immersed for the period of time indicated on the disinfectant packaging, and associated with the concentration chosen for the preparation of the solution.
- Recover disinfected components and rinse them thoroughly with warm drinking water.
- Dispose the solution according to the indications provided by the disinfectant manufacturer.
Method B: disinfect the accessories by boiling in water for 10 minutes; use demineralized or distilled water to avoid limestone deposits.
Method C: disinfect accessories with a hot vaporizer for steam bottle (not microwave). Perform the process faithfully following the instructions of the vaporizer. In order for disinfection to be effective to choose a vaporizer with an operating cycle of at least 6 minutes.
After disinfecting the accessories, shake them energetically and place them on a paper napkin, or alternatively wipe them with a hot air jet (for example hairdryer).
At the end of each use store the appliance complete with accessories in a dry place and protected from dust.
Warnings
The medical device should not be used for patients not able to breathe independently or unconsciously.
Do not use the device in anesthetic circuits or assisted ventilation.
Use the device exclusively as a therapeutic inhaler.
This medical device is not intended as a life saving device.
Any different uses are to be considered improper and can be dangerous.
Always address your doctor for the identification of the cure.
Follow the indications of your doctor or therapist of respiratory rehabilitation with regard to the type of medicine, the dosage of treatment indications.
If allergic reactions or other problems occur while using the device, stop using it immediately and consult your doctor. Do not expose the appliance at particularly extreme temperatures.
Do not place the appliance near heat sources, in sunlight or in too hot environments.
The time necessary to pass from the conditions of conservation to those of exercise is about 2 hours.
It is forbidden to access the compressor unit in any way.
Repairs must be carried out only by authorized personnel from the manufacturer.
Unauthorized repairs cancel the warranty and may pose a danger to the user.
Smoothing risk: some components of the appliance are so small that they can be swallowed by children; store the appliance outside the reach of children.
Risk strangulation: Do not use the connecting tube and cables provided outside the intended use, the same could cause danger of strangulation, pay particular attention to children and people with particular difficulties, often these people are unable to properly assess the dangers.
Fire risk: it is a device not suitable for use in the presence of flammable anesthetic mixture with air, or with oxygen or with nitrogen oxide.
Risk of foulage: prior to the first use, and periodically during the life of the product, check the integrity of the structure of the appliance and the power cord to ensure that there is no damage; if damaged, do not insert the plug and immediately bring the product to a service center.
Keep the power cord away from animals (for example, rodents), otherwise such animals could damage the insulation of the power cord.
Always keep the power cord away from hot surfaces.
Never block aeration slots placed on both sides of the compressor unit.
Do not handle the compressor unit with wet hands.
Do not use the compressor unit in wet environments (for example while bathing or showering).
Do not immerse the compressor unit in the water; if this happens, remove the plug immediately.
Do not extract or touch the compressor unit immersed in water, first unplug the plug.
Format
1 piece.
Co AN13P
Medical device for administering drugs through inhalation, whose inhalation therapy and medicines must be prescribed by your doctor. Treatment of respiratory diseases.
Drugs must be prescribed by a doctor who has assessed the patient's general condition.
Assembly
Assemble the nozzle on the top.
Place the valve on the grain size regulator with the flat side facing down and aligning the hole with the position ribs, then screw the selector onto the regulator's threaded pin until it stops.
Rotate the assembled regulator to ensure it rotates freely and that the selector moves up and down between positions.
Insert and press the previously assembled grain size regulator all the way in, keeping it in a horizontal position, in the upper part, making sure the selector bulkheads match the recess in the upper part.
Insert the upper part assembled at the bottom and attach it by turning it clockwise.
Mode of use
Before use, wash your hands thoroughly.
During the application it is recommended to protect itself adequately from any dripping.
This nebulizer is suitable for the administration of medicinal substances (solutions and suspensions), for which aerosolic administration is expected, such substances must be prescribed by the doctor.
In the case of too dense substances it may be necessary to dilute with suitable physiological solution, according to prescription.
Insert the power cord plug into an electrical socket corresponding to the voltage of the appliance.
The same must be positioned in such a way that it is not difficult to operate the disconnection from the electricity network.
Pour the medicine prescribed by your doctor at the bottom.
Insert the upper part of the amp at the bottom, close the amp by turning the upper part clockwise.
Connect the accessories.
Set the amp selector for the desired granulometry.
Sit comfortably holding the nebulizer, lean the mouthpiece or use the nasal (where required) or mask.
In case you use the mask accessory to support the face.
Put the appliance into operation by activating the switch and inhale and exhale deeply.
It is recommended after the inspiration to hold your breath for an instant so that inhaled aerosol drips can settle.
Exhale slowly.
Finish the application, turn off the appliance and disconnect it from the power grid.
Cleaning and disinfection
Switch off the appliance before any hygienic preparation operation and disconnect it from the power grid.
Compressor and external unit of the pipe: use only a moistened cloth with antibacterial cleaner (non abrasive and solvent-free of any kind).
Nebulizer and accessories: open the nebulizer by turning the top anti-clockwise, detach the nozzle and the speed selector from the top. Then proceed according to the instructions below.
Sanification.
Before and after each use, sanitize the nebulizer and accessories by choosing one of the methods described below.
Method A: sanitize the accessories under drinking hot water (about 40°C) with mild detergent for dishes (not abrasive).
Method B: sanitizing dishwasher accessories with hot cycle (70°C).
Method C: sanitize the accessories by dive into a solution with 50% water and 50% white vinegar, then rinse thoroughly with drinking hot water (about 40°C). After sanitizing the accessories shake them energetically and attach them on a paper napkin, or alternatively wipe them with a hot air jet (for example hairdryer).
Disinfection.
After sanitizing the nebulizer and accessories, disinfect them by choosing one of the methods provided and described below. Each method is feasible for a limited number of times.
Method A: Procuring an electrolytic chloxydant disinfectant (active ingredient: sodium hypochlorite), specific for disinfection available in all pharmacies.
Execution:
- Fill a container of dimensions suitable to contain all individual components to be disinfected with a solution based on drinking water and disinfectant, respecting the proportions indicated on the packaging of the disinfectant.
- Completely immerse every single component in the solution, taking care to avoid the formation of air bubbles in contact with the components. Leave the components immersed for the period of time indicated on the disinfectant packaging, and associated with the concentration chosen for the preparation of the solution.
- Recover disinfected components and rinse them thoroughly with warm drinking water.
- Dispose the solution according to the indications provided by the disinfectant manufacturer.
Method B: disinfect the accessories by boiling in water for 10 minutes; use demineralized or distilled water to avoid limestone deposits.
Method C: disinfect accessories with a hot vaporizer for steam bottle (not microwave). Perform the process faithfully following the instructions of the vaporizer. In order for disinfection to be effective to choose a vaporizer with an operating cycle of at least 6 minutes.
After disinfecting the accessories, shake them energetically and place them on a paper napkin, or alternatively wipe them with a hot air jet (for example hairdryer).
At the end of each use store the appliance complete with accessories in a dry place and protected from dust.
Warnings
The medical device should not be used for patients not able to breathe independently or unconsciously.
Do not use the device in anesthetic circuits or assisted ventilation.
Use the device exclusively as a therapeutic inhaler.
This medical device is not intended as a life saving device.
Any different uses are to be considered improper and can be dangerous.
Always address your doctor for the identification of the cure.
Follow the indications of your doctor or therapist of respiratory rehabilitation with regard to the type of medicine, the dosage of treatment indications.
If allergic reactions or other problems occur while using the device, stop using it immediately and consult your doctor. Do not expose the appliance at particularly extreme temperatures.
Do not place the appliance near heat sources, in sunlight or in too hot environments.
The time necessary to pass from the conditions of conservation to those of exercise is about 2 hours.
It is forbidden to access the compressor unit in any way.
Repairs must be carried out only by authorized personnel from the manufacturer.
Unauthorized repairs cancel the warranty and may pose a danger to the user.
Smoothing risk: some components of the appliance are so small that they can be swallowed by children; store the appliance outside the reach of children.
Risk strangulation: Do not use the connecting tube and cables provided outside the intended use, the same could cause danger of strangulation, pay particular attention to children and people with particular difficulties, often these people are unable to properly assess the dangers.
Fire risk: it is a device not suitable for use in the presence of flammable anesthetic mixture with air, or with oxygen or with nitrogen oxide.
Risk of foulage: prior to the first use, and periodically during the life of the product, check the integrity of the structure of the appliance and the power cord to ensure that there is no damage; if damaged, do not insert the plug and immediately bring the product to a service center.
Keep the power cord away from animals (for example, rodents), otherwise such animals could damage the insulation of the power cord.
Always keep the power cord away from hot surfaces.
Never block aeration slots placed on both sides of the compressor unit.
Do not handle the compressor unit with wet hands.
Do not use the compressor unit in wet environments (for example while bathing or showering).
Do not immerse the compressor unit in the water; if this happens, remove the plug immediately.
Do not extract or touch the compressor unit immersed in water, first unplug the plug.
Format
1 piece.