Descrizione Clinica
Thermometers - traditional thermometers - temperature devices Ch thermometer flex night Chicco
Chicco
Flex Night Plus Thermometer
Description
Rectal and oral clinical thermometer.
It detects the temperature in only 10 sec.
The flexible tip provides high comfort during temperature detection.
The large bright display and the silensious mode allow you to view the temperature even at night without waking the child.
The thermometer and its probe can be cleaned using a cotton ball with alcohol or disinfectant solutions. The probe is waterproof. The tool is not waterproof, do not immerse it or let water or other liquids enter. Never use abvrasive detergents, solvents or benzene: these could damage or contaminate the thermometer casing.
Mode of use
1. Turn on the thermometer by pressing the ON/ button/OFF
2. The following writings will appear on the viewer: "Last measure" (e.g. 36.0°C M/96.8°F M)" "Lo°C/Lo°F" with °C/°F flashing to indicate the start of the measurement;
3. Place the thermometer:
a. Oral use (10 sec.): place the probe tip at the bottom of the mouth, under the tongue and close the mouth.
b. Rectal use (10 sec.): insert the probe tip in the rectum for some mm (no more than 15 mm). If resistance is detected during this operation immediately stop. To measure the temperature to the newborn by rectal means, lay it on a rigid plane on one side and move the stems to the chest keeping it firm so that it can not turn during the measurement. Remember that the internal body temperature is always slightly higher than the external temperature (about 0.5°C). Do not use ointments or vaselline on the tip.
4. An acoustic signal alerts you to the detection. The display is illuminated for a few seconds to facilitate the reading of the temperature. _ If the temperature is ? 37.8 °C (? 100.0 °F), the sound indicator emits a sound and shows the icon with the sad face.
5. If the Lo°C/ Lo°F sign is displayed, the thermometer has measured a temperature below the minimum value of the measuring range. If the Hi°C/ Hi°F sign is displayed, the thermometer has measured a temperature higher than the maximum value of the measuring range. In these cases it is suggested to check the correct positioning of the thermometer and repeat the measurement. If the word "ERR" appears, the thermometer has operating problems: contact the Consumer Service.
6. After detection turn off the thermometer by pressing the button (if it is forgotten on it will turn off alone after about 10 minutes). If the word "ERR" appears, the thermometer has operating problems: contact the Consumer Service.
PRCAUTIONS MISURA ACCELERATE
As a direct measuring thermometer and robbery, it is recommended to use rectal and oral. If an axillary measurement is required, take these precautions to allow the axillary temperature to stabilize:
-make sure the armpit is dry;
-neck the tip of the thermometer off and tighten the arm against the body remaining in this position for about 60 seconds before measuring;
-proceed to the measurement as indicated in the paragraph "Terms of Use".
Warnings
Before and after each measurement clean and sanitize the probe.
Keeping in safe place and away from the reach of children, is not a toy.
Never leave only the child during temperature measurement.
The thermometer contains small parts (battery, etc.) that can be swallowed by children and lead to suffocation or internal injuries.
Any use on subjects with reduced cognitive capacity or on the child must be supervised by an adult: during temperature measurement, the tip of the measuring probe may become dangerous if it is near the eyes.
The thermometer is intended exclusively for measuring body temperature.
If you have any impacts, falls or if you have any doubts about the operation of the product, please contact the distributor.
Don't try to fix the thermometer.
In case of doubt or temperature rise consult your doctor.
After use store the thermometer in a cool and dry place and sheltered from dust.
The thermometer, after its first use and between subsequent uses, must be kept under temperature and humidity conditions that meet the specified limits for transport and storage conditions.
The correct positioning of the thermometer is essential for accurate temperature detection.
Avoid drinking hot or cold drinks, doing physical activity, bathing or showering and smoking during 15 minutes before measuring.
Thermometer for direct measurement, for rectal and oral use; axillary use allowed with precautions debits.
No need for recalibration.
Conservation
Temperature range for storage: -20°C~55°C.
Humidity range for storage: 15%-95% UR without condensation.
Atmospheric conservation pressure range: 700-1060hPa.
Cod. 00009812000000
Rectal and oral clinical thermometer.
It detects the temperature in only 10 sec.
The flexible tip provides high comfort during temperature detection.
The large bright display and the silensious mode allow you to view the temperature even at night without waking the child.
The thermometer and its probe can be cleaned using a cotton ball with alcohol or disinfectant solutions. The probe is waterproof. The tool is not waterproof, do not immerse it or let water or other liquids enter. Never use abvrasive detergents, solvents or benzene: these could damage or contaminate the thermometer casing.
Mode of use
1. Turn on the thermometer by pressing the ON/ button/OFF
2. The following writings will appear on the viewer: "Last measure" (e.g. 36.0°C M/96.8°F M)" "Lo°C/Lo°F" with °C/°F flashing to indicate the start of the measurement;
3. Place the thermometer:
a. Oral use (10 sec.): place the probe tip at the bottom of the mouth, under the tongue and close the mouth.
b. Rectal use (10 sec.): insert the probe tip in the rectum for some mm (no more than 15 mm). If resistance is detected during this operation immediately stop. To measure the temperature to the newborn by rectal means, lay it on a rigid plane on one side and move the stems to the chest keeping it firm so that it can not turn during the measurement. Remember that the internal body temperature is always slightly higher than the external temperature (about 0.5°C). Do not use ointments or vaselline on the tip.
4. An acoustic signal alerts you to the detection. The display is illuminated for a few seconds to facilitate the reading of the temperature. _ If the temperature is ? 37.8 °C (? 100.0 °F), the sound indicator emits a sound and shows the icon with the sad face.
5. If the Lo°C/ Lo°F sign is displayed, the thermometer has measured a temperature below the minimum value of the measuring range. If the Hi°C/ Hi°F sign is displayed, the thermometer has measured a temperature higher than the maximum value of the measuring range. In these cases it is suggested to check the correct positioning of the thermometer and repeat the measurement. If the word "ERR" appears, the thermometer has operating problems: contact the Consumer Service.
6. After detection turn off the thermometer by pressing the button (if it is forgotten on it will turn off alone after about 10 minutes). If the word "ERR" appears, the thermometer has operating problems: contact the Consumer Service.
PRCAUTIONS MISURA ACCELERATE
As a direct measuring thermometer and robbery, it is recommended to use rectal and oral. If an axillary measurement is required, take these precautions to allow the axillary temperature to stabilize:
-make sure the armpit is dry;
-neck the tip of the thermometer off and tighten the arm against the body remaining in this position for about 60 seconds before measuring;
-proceed to the measurement as indicated in the paragraph "Terms of Use".
Warnings
Before and after each measurement clean and sanitize the probe.
Keeping in safe place and away from the reach of children, is not a toy.
Never leave only the child during temperature measurement.
The thermometer contains small parts (battery, etc.) that can be swallowed by children and lead to suffocation or internal injuries.
Any use on subjects with reduced cognitive capacity or on the child must be supervised by an adult: during temperature measurement, the tip of the measuring probe may become dangerous if it is near the eyes.
The thermometer is intended exclusively for measuring body temperature.
If you have any impacts, falls or if you have any doubts about the operation of the product, please contact the distributor.
Don't try to fix the thermometer.
In case of doubt or temperature rise consult your doctor.
After use store the thermometer in a cool and dry place and sheltered from dust.
The thermometer, after its first use and between subsequent uses, must be kept under temperature and humidity conditions that meet the specified limits for transport and storage conditions.
The correct positioning of the thermometer is essential for accurate temperature detection.
Avoid drinking hot or cold drinks, doing physical activity, bathing or showering and smoking during 15 minutes before measuring.
Thermometer for direct measurement, for rectal and oral use; axillary use allowed with precautions debits.
No need for recalibration.
Conservation
Temperature range for storage: -20°C~55°C.
Humidity range for storage: 15%-95% UR without condensation.
Atmospheric conservation pressure range: 700-1060hPa.
Cod. 00009812000000